TRANSFORMERS COMMITTEE

Insulation Life Subcommittee

Insulation Life Subcommittee Scope

  • Study and review methods to determine maximum safe insulation temperatures, ambient temperatures, insulation aging characteristics, safe duration of loads in excess of nameplate (including short circuits) and also to determine methods of calculating or measuring temperatures reached during both transient and steady state loads.
  • Develop and maintain related standards, recommended practices and guides for such criteria.
  • Coordinate with other technical committees, groups, societies and associations as required.

Chair

Bruce Forsyth

Southwest Electric Company

Oklahoma City, OK 

U.S.A.

Phone: (405) 622-8816

E-Mail: bruce.forsyth@ieee.org

Vice-Chair

Barry Beaster

ABB Kuhlman

Crystal Springs, MO

U.S.A.

Phone: (601) 892-6439

E-Mail: blbeaster@ieee.org

Secretary

Eric Davis

Burns & McDonnell

Kansas City, MO

USA

Phone: (816) 822-3925

E-Mail: edavis@burnsmcd.com

Status

Fall 2011 Agenda   posted 19Oct2011

Proposed New WG on High Temperature TRs  posted 16Mar2008

Tie-plate Insulation Limits  posted 16Mar2008

Minutes of Previous Meetings

See Transformers Committee Minutes

Working Groups/Task Forces
  • WG - WTI

Paper - Requirements of Winding Temperature Indicators for the Rapid Response and Accurate Measurement of the Hottest Spot Winding Temperature in Liquid Filled Power Transformers, Draft 9:  Posted 16Mar2006

  • TF - Definition of Thermally Upgraded Insulation

  • TF - Furans

Furan Report, Final Draft: posted 4Apr2011  The Committee password is required to access this document.

  • TF - C57.12.00, Clause 5 - Temperature Rise Test

  • WG – C57.12.90  Clause 11.0 - Temperature Rise Test
    Chair: Paulette Payne Powell
    Vice Chair: Juan Castellanos
    Secretary: Marnie Roussell

Fall 2011 Minutes   posted 19Jan2012

Ballot Survey Summary 11.1 and 11.1.2.2   posted 05Oct2011

Ballot Survey 11.2.2 Summary - July 6, 2011   posted 31Aug2011

Straw Ballot e-mail  posted 10Mar2010

C57.12.90 Clause 11.2.2 Final Draft   updated 04Mar2010

Fall 2009 Presentation by B. Poulin  posted 23Oct2009

Fall 2009 Paper by B. Poulin  posted 23Oct2009

Fall 2009 Presentation by S. Som  posted 25Oct2009

Presentation by Roizman & Davydov  posted 2Jul2009

Hot Resistance Case Studies  posted 4Apr2009

Snyder Cooling Curve Data  posted 4Apr2009

Snyder 10 minute Cooling Curve Data  posted 4Apr2009

Thermal BLUME  posted 4Apr2009

Fortin Transformer coil average temperature  Updated 22Apr2009

Previous Meeting Documents:

Fall 2006 Presentation, "Comparison of Thermal Test Data"  posted 16Oct2006

Hot resistance measurements on a GSU - by Mark Perkins  posted 2Oct2007

Hasse Nordman's presentation for the meeting, Average Oil Temperature in Distribution Transformers  posted 2Oct2007

Thermal Calculations - BLUME Method  (2.6MB) posted 21Apr2006

Hot Resistance - Heat Run Procedure  posted 24Apr2006

C57.12.90 Clause 11 proposal  posted 3Mar2006

Average Oil Temperature Rise in Distribution Transformers Without an External Oil Circulation, by Hasse Nordman

Fall 2008 Agenda  posted 24Oct2008

Fall 2008 Task Force Minutes  posted 24Oct2008

This page is maintained by: webmaster

Last update: 19-Jan-2012

IEEE prohibits discrimination, harassment and bullying.  For more information, visit http://www.ieee.org/web/aboutus/whatis/policies/p9-26.html